Publications, Pharmaceutical

Performance of Low-GWP Propellants in pMDIs: Filling and Dose Evaluation

The increasing concern over climate change has prompted the development of new propellants with low global warming potential (GWP) for pressurized metered dose inhalers (pMDIs). The aim is to replace the currently used hydrofluoroalkanes (HFAs), such as 134a and 227, with more environmentally friendly alternatives in accordance with the Kigali Amendment to the Montreal Protocol. Two potential candidates for these new propellants are HFA 152a and HFO 1234ze(E), which are being investigated for their filling and dose performance in pMDIs.

Download Publication "Performance of Low-GWP Propellants in pMDIs: Filling and Dose Evaluation"
Author(s): Grégoire Deraime José Ferrao Laurence Caneque Bueno Emma Alix Gerallt Williams
3 Jul 2023

One crucial aspect of transitioning to low GWP propellants is ensuring that the existing hardware, including metered dose valves, is compatible with the new formulations. Additionally, it is essential to verify that the new pMDIs perform at least as well as, if not better than, the current HFA-based inhalers. This study focuses on evaluating key performance characteristics related to canister filling, leakage, and dose weight delivery.

To facilitate the filling process, new pilot scale equipment specifically designed for low GWP propellants was successfully employed. The researchers were able to accurately and reproducibly fill optimized metered dose inhalers using these novel propellants. Static leakage, which measures the amount of propellant escaping from the canister, was found to be within the established regulatory limits for the low GWP inhalers. Moreover, the dose delivery performance remained acceptable for a period of up to six months of shelf life when utilizing the new pMDI valves. Importantly, the performance of the low GWP pMDIs was either equivalent to or superior to that of the currently used HFA-based inhalers.

Based on these findings, both HFA 152a and HFO 1234ze demonstrate promise as suitable replacements for the current HFAs in pMDIs. These new propellants offer the potential to meet the global targets set for the phase-down of F-Gases in the coming years. By transitioning to low GWP alternatives, the medical industry can contribute to mitigating the impact of greenhouse gas emissions and align with efforts to combat climate change.

In conclusion, this research highlights the successful development and evaluation of pMDIs using new low GWP propellants. The study demonstrates that the filling process can be effectively performed with specialized equipment, while leakage remains within acceptable limits. Furthermore, the dose delivery performance of the new pMDIs is comparable to or better than the current HFA-based inhalers. These findings provide a strong foundation for the future adoption of low GWP propellants in pMDIs, promoting sustainable healthcare practices and environmental stewardship.

Learn more about Aptar Pharma Expertise
in Inhalation Drug Delivery

Find Out More About inhalation drug delivery expertise

This Might Also Be of Interest

2 Nov 2021

Successfully Balancing The Needs of The Planet With The Needs of The Patient

Publications, Pharmaceutical, Product Solutions, Sustainability, Innovation & Insights, Device Innovations

Read More
26 Oct 2021

Using digital healthcare to improve patient compliance and adherence

Webinars, Pharmaceutical, Innovation & Insights, Device Innovations, Brand Differentiation, Product Solutions

Read More
28 Sep 2021

Towards a More Sustainable Future with Metered Dose Inhalers

Webinars, Pharmaceutical, Brand Differentiation, Market Insights, Product Solutions, Sustainability, Device Innovations

Read More
1 Jul 2021

Moving Toward a More Sustainable Future With pMDIs

Publications, Pharmaceutical, Sustainability, Innovation & Insights, Device Innovations, Brand Differentiation, Product Solutions

Read More
1 8 9 10 11 12 19

Request Access

Close

Requesting access to Performance of Low-GWP Propellants in pMDIs: Filling and Dose Evaluation.

  • This field is for validation purposes and should be left unchanged.
Back To Top